Energy Balance Station (DAM)
* Measurements @ 20 Hz:
- abs. humidity measurements at 4m height (LiCor 7500)
- CO2 measurements at 4m height (LiCor 7500)
- Dewpoint measurements at 4m height (Meteolabor SnowWhite 32)
- 3-component wind measurements (u, v, w) by ultrasonicanemometer at 4m height (Gill)
* Measurements @ 1 Hz
- temperature measurements at 0.5m and 2.8m height (HMP 35)
- rel. humidity measurements at 0.5m and 2.8m height (HMP 35)
- precipitation measurements (Hellmann)
- air pressure measurements (Setra)
- long wave radiation from upper and lower half space (Schulze)
- short wave radiation from upper and lower half space (Kipp & Zonen (CM 14))
- soil heat flux (Scott- Carter Design (CN3))
- soil temperature measurements (Heimann (KT 15))
* Site and position:
Dam at Pump station 5, north of Ein Bokek:
N 31°14'06.1", E 035°22'03.2", Altitude -399 m
* Period of data acquisition:
2006-09-29 15:00 UTC - 2006-10-11 06:10 UTC
* Average interval: 10 min